{"product_id":"uni-t-ut890d-true-rms-digital-multimeter-6000-counts-with-ncv-live-test","title":"UNI-T UT890D+ True RMS Digital Multimeter (6000 Counts with NCV \u0026 LIVE Test)","description":"\u003cp data-path-to-node=\"5\" id=\"p-rc_ae38ef64957c7e3a-329\"\u003eWhat specifically distinguishes the \"D+\" variant of the UT890 series is its focus on electrician safety and AC mains diagnostics. It swaps out the temperature probe of the C-model in favor of an advanced Non-Contact Voltage (NCV) detector and a highly useful \"LIVE\" wire testing function. This allows you to quickly distinguish between live and neutral wires using just a single test probe. Furthermore, it boasts an absolutely massive capacitance testing range (up to 100mF), allowing you to test large power supply capacitors that lesser meters simply cannot read. \u003cspan class=\"citation-489 citation-end-489\"\u003eHoused in UNI-T's signature rugged, drop-resistant over-molding and featuring a highly unique \"blown fuse\" audible alarm, it is designed to keep both you and the meter completely safe during intense electrical work.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003eKey Features \u0026amp; Functional Advantages\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\" id=\"p-rc_ae38ef64957c7e3a-330\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eTrue RMS Measurement:\u003c\/b\u003e\u003cspan class=\"citation-488 citation-end-488\"\u003e Delivers highly accurate AC voltage and current readings on complex, non-sinusoidal electrical waveforms where standard meters would incorrectly calculate the values.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\" id=\"p-rc_ae38ef64957c7e3a-331\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eNCV \u0026amp; LIVE Wire Testing:\u003c\/b\u003e\u003cspan class=\"citation-487 citation-end-487\"\u003e Features a built-in sensor for detecting AC voltage safely without contact, plus a dedicated LIVE function that uses a single probe to identify the hot wire in an AC outlet with an audible and visual alarm.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\" id=\"p-rc_ae38ef64957c7e3a-332\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eMassive Capacitance Range:\u003c\/b\u003e\u003cspan class=\"citation-486 citation-end-486\"\u003e Capable of elegantly measuring up to 100mF (100,000μF), making it incredibly useful for repairing audio amplifiers and heavy-duty motor start capacitors.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\" id=\"p-rc_ae38ef64957c7e3a-333\"\u003e\u003cspan class=\"citation-485\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-485\"\u003eIntelligent Fuse Alarm:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-485 citation-end-485\"\u003e Features a brilliant built-in safety warning system that audibly and visually alerts you if the internal protection fuses have blown, preventing you from chasing false diagnostic readings.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\" id=\"p-rc_ae38ef64957c7e3a-334\"\u003e\u003cspan class=\"citation-484\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-484\"\u003eHigh Current Capacity:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-484 citation-end-484\"\u003e Designed to safely handle up to 20 Amps of continuous current, significantly outperforming the standard 10-Amp limit found on most handheld meters.\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003ePerfect For\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eElectricians \u0026amp; Household Maintenance:\u003c\/b\u003e The absolute best choice for safely tracing live wires, testing AC outlets, and diagnosing breaker panels using the NCV and LIVE functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eAdvanced Electronics Repair:\u003c\/b\u003e The massive capacitance range and True RMS capabilities make it perfect for fixing modern flat-screen televisions and switching power supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eIndustrial Maintenance:\u003c\/b\u003e Safely verifying high-voltage mains and accurately testing variable-frequency drives on the factory floor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eHardware Engineering:\u003c\/b\u003e A trustworthy, highly accurate bench meter for verifying complex logic circuits and measuring precise resistor and capacitor values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eDevice Type:\u003c\/b\u003e True RMS Manual-Ranging Digital Multimeter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eDisplay:\u003c\/b\u003e 6000 Counts LCD with Backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eDC Voltage Range:\u003c\/b\u003e 600.0mV to 1000V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eAC Voltage Range:\u003c\/b\u003e 6.000V to 750V (True RMS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\" id=\"p-rc_ae38ef64957c7e3a-335\"\u003e\u003cspan class=\"citation-483\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-483\"\u003eDC\/AC Current Range:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-483 citation-end-483\"\u003e 60.00μA to 20.00A\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eResistance Range:\u003c\/b\u003e 600.0Ω to 60.00MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-path-to-node=\"11,6,0\" data-index-in-node=\"0\"\u003eCapacitance Range:\u003c\/b\u003e 6.000nF to 100.0mF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\"\u003e\u003cb data-path-to-node=\"11,7,0\" data-index-in-node=\"0\"\u003eFrequency Range:\u003c\/b\u003e 9.999Hz to 9.999MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,8,0\" id=\"p-rc_ae38ef64957c7e3a-336\"\u003e\u003cb data-path-to-node=\"11,8,0\" data-index-in-node=\"0\"\u003eExtra Functions:\u003c\/b\u003e\u003cspan class=\"citation-482 citation-end-482\"\u003e NCV (Non-Contact Voltage), LIVE Wire Test, Blown Fuse Alarm, Transistor hFE, Diode Test, Continuity Buzzer, Data Hold\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,9,0\"\u003e\u003cb data-path-to-node=\"11,9,0\" data-index-in-node=\"0\"\u003ePower Source:\u003c\/b\u003e 2 x 1.5V AAA Batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,10,0\" id=\"p-rc_ae38ef64957c7e3a-337\"\u003e\u003cb data-path-to-node=\"11,10,0\" data-index-in-node=\"0\"\u003eSafety Rating:\u003c\/b\u003e\u003cspan class=\"citation-481 citation-end-481\"\u003e CAT II 1000V \/ CAT III 600V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"K-TECHNICS","offers":[{"title":"Default Title","offer_id":42878654939207,"sku":null,"price":3500.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7637\/2039\/files\/UT890D_1.jpg?v=1781509820","url":"https:\/\/www.ktechnics.com\/products\/uni-t-ut890d-true-rms-digital-multimeter-6000-counts-with-ncv-live-test","provider":"K-TECHNICS","version":"1.0","type":"link"}